Solenoid valve setDetailed parametersP port pressureMaximum flowVoltage rangeAccumulator volumeAllowable ambient operating temperatureOil temperature range40bar15L/minDC27V±15%; plug DTO4-2P, rated power 23.8W, protection level IP670.32L, precharge pressure 10bar-20-80℃-20-90℃Product applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
Contact Now
The working principle of the solenoid valve is that it contains a closed cavity inside the solenoid valve. In the middle of the cavity is a piston, and on both sides of the cavity are two electromagnets.
Contact Now
hydraulic solenoid valveDetailed parametersRated pressureMaximum flowVoltage range Coil built-in diodeAllowable ambient operating temperatureOil temperature range70bar30L/minDC27V±15%; plug DTO4-2P, Rated power 23.8W, protection level IP67model RL257, Rated reverse voltage 1000V, rated current 2.5A, instantaneous peak current 100A-20-80℃-20-90℃Application Scenarios:Our customized hydraulic valve blocks represent the top level of hydraulic control technology, designed with a focus on performance, reliability and durability.
Contact Now
Solenoid reversing valvedirectional valve1. Control the pressure of the hydraulic systemThe hydraulic control valve can change the pressure and stability of the hydraulic system by adjusting the opening size and opening method in the valve core, so as to meet the work needs of different pressure requirements. 2.
Contact Now
Solenoid Valve Parts SD2E-A4/H2R21Product applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
Contact Now
hydraulic solenoid valveDetailed parametersMaximum working pressureMaximum decompression pressureRated flow rateProportional valveMaximum currentProtection levelAllowable pollutionSwitch valveAllowable ambient operating temperatureThe oil temperature range50 bar30 bar10L/minRated voltage: 24V, connector DT04-2P750mA, resistance: 20.8 Ω±5%IP6k6/IPX9K ISO 4406 class 20/18/15Voltage range DC27V±15%, plug DTO4-2P, protection level IP67;-20-80℃-20-90℃It is mainly composed of valve body, valve, electromagnet, etc.Among them, the valve is the most critical part of the quadruple solenoid valve.
Contact Now
Solenoid Valve Parts SP2A-B3H3S-AProduct applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
Contact Now
Two solenoid hydraulic valvesDetailed parametersRated pressureMaximum decompression pressureProportional valve 2 Rated voltageMaximum coil currentCoil resistance at 20℃Optimized PWM frequencySolenoid valve 3 rated voltageAllowable ambient operating temperatureOil temperature range50 bar30 barDC 24V500mA31Ω±5 %600HZ, connector DT04-2PDC24V±10%, connector DT04-2P -20-80℃The working principle of the two-in-one solenoid valve mainly involves the interaction of the electromagnet, the valve body and the valve core, and controls the mechanical movement by controlling the current on and off of the ele
Contact Now
The double solenoid valve belongs to a kind of solenoid valve, and its structure is composed of an electromagnetic spring ring, a valve body, a piston, a spring, a valve seat, a gasket and other parts.Its main feature is that it has two outlets and one inlet, each outlet has a piston, and the entire device is equivalent to two check valves.structureThe double solenoid valve is composed of two parts: an electromagnet and a valve body.The electromagnet is composed of three parts: a coil, a contact, and an iron core.
Contact Now
Please leave a message or send an email for details to ensure that you are satisfied with the price1.
Contact Now
Solenoid Valve Parts SD4E-A4/H2Y21Two-position four-way directional control valve, electromagnetic control spool valve type, direct-acting high-performance typeMaximum flow rate 30L/minMaximum working pressure 350barOperating ambient temperature range -20°C-80°C、Fluid temperature range -20°C-80°CProduct applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
Contact Now
Solenoid Reversing Valve Parts SD1E-A2/H2S5-ATwo-position two-way directional control valve, electromagnetic control, cone valve type, no leakage, direct-actingTwo-position two-way high-pressure direct-acting spool valve type threaded cartridge reversing valve.
Contact Now
Two-position three-way solenoid hydraulic valveDetailed parameters:Working pressureMaximum flow rateVoltage rangePlug connection modelElectromagnetic coil protection levelSolenoid valve powerCheck valve opening pressureAllowable pollutionAllowable working ambient temperatureOil viscosity range50bar30L/min DC27V±15% DT04-2PIP67<30W1bar, diameter 821/18/15 -30℃--90℃ ISO 20--400mm2/SApplication Scenarios:Our customized hydraulic valve blocks represent the top level of hydraulic control technology, designed with a focus on performance, reliability and durability.
Contact Now
Solenoid Valve PartsUsed as cut-off or load-holding oil equipment in low-flow oil circuitsWorking pressure: 207barWithstand pressure: 255barTemperature range: -40°C-120°C standard nitrile rubber sealProduct applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
Contact Now
hydraulic solenoid valve Structure and flow path diagramTwo-position six-way directional control valve, also known as two-position six-way control valve, its main structure is composed of import and export interface, valve body, valve core, control lever and other parts, wherein the valve body is provided with a corresponding flow channel, used to control the direction of fluid in and out.The flow path diagram is shown below:Among them, A, B, P, and C are the inlet, outlet, internal connection port, and control port respectively.Among them, ports A and B can be connected to different hydraulic
Contact Now
Solenoid Valve Parts SV08-20HJ-O-N-OUsed as cut-off or load-holding oil equipment in low-flow oil circuitsWorking pressure 207barWithstand pressure 255barThe maximum internal leakage is 0.15ml/min at 207barTemperature range -40°C-120°C, standard nitrile rubber sealThe rated load of the coil can operate continuously in the rated voltage range of 85% to 115% Product applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
Contact Now
Can be customized according to customer needs Customized case:1.Maximum working pressure: 50 bar; 2.Maximum decompression pressure: 30 bar; 3.Rated flow rate: 10L/min; 4.Rated voltage: 12V, connector DT04-2P, protection level IP67; 5.Maximum current: 1500mA, resistance: 4.72 Ω±5%; 6.Filter: 140 µm (P-Port); 7.Protection level: IP6k6/IPX9K.
Contact Now
PrincipleElectromagnetic reversing valve is a device that uses the principle of electromagnetic mechanics to control the state of the oil port.
Contact Now
The solenoid valve, made from hardened precision parts, provides high flow capacity and efficient hydraulic energy transmission, with all ports capable of full pressure loading. Application1. Application in the field of industrySolenoid valves are widely used in various industrial automation systems, such as transmission line, robot, metallurgy, chemical industry, water conservancy, electric power and other fields.
Contact Now
Customized hydraulic valve setDetailed parametersRated pressureSystem oilRated voltageOil port specificationsIntegrated block materialAccumulator Volume:FilterPressure setting40 BarHydraulic oil: Mineral hydraulic oil of ISO VG32, 46 and 68Viscosity range: 10-500 mm2/sCleanliness level: 21/18/15 According to ISO4406 (1999)Oil temperature range: -20~80℃27V±15%, connector DT04-2P P T PORT: G3/4-ED (DIN3852-2); A PORT: G3/8-ED (DIN3852-2);P1,P2, C1-C6, M,M1: G1/4-ED (DIN3852-2); M,M1 is blocked with steel.AL-6061-T6, surface anodized1L; inflation pressure: 15 baraccuracy 10um; flow rate: 160L/min
Contact Now
The lower oil cylinder, used for lifting cylinder action control, features throttle damping for descent speed regulation, precise flow control through a proportional valve, and minimal vibration. It includes a solenoid valve with manual operation for platform descent in the absence of power and an overflow valve for oil circuit safety. The function of the lifting oil cylinderLift cylinder is to use liquid medium to convert mechanical energy into hydraulic energy, and through operation to achieve load lift or drop.
Contact Now
Product customization display (hydraulic valves types)A bypass valve is a control valve used to control the flow and pressure of fluid in a pipeline.Its structure is relatively simple, usually composed of valve body, valve core, spring, etc.When the valve core is under pressure, it will move to a specific position, thereby changing the size of the channel in the valve, thereby adjusting the flow and pressure.Main functions1. Control flow: The most important function of the bypass valve is to regulate the flow of fluid.
Contact Now
Floating balance valve is an automatic regulating valve, commonly used in piping systems, by automatically adjusting the flow and pressure to maintain the stability of the system, and to prevent the pressure from being too high or too low.It is suitable for various fluid media and piping systems, and can provide reliable flow control and pressure regulation functions for the system.principleThe working principle of the floating balance valve is based on its special design structure.It consists of the main valve body, the valve core and the regulating spring.When the liquid flows into the main
Contact Now
Hydraulic check valveDetailed parametersThe maximum working pressure The opening pressureRated flow250bar4barrate 150 liters/minHydraulic check valveA directional control valve where air flow or liquid can only flow in one direction and cannot flow in reverse.The working principle is a sphere, in a cone.When the liquid passes from one end of the cone to the other, push the sphere away and pass through.When passing in reverse, the sphere clogs the channel and the liquid cannot pass through.Application Scenarios:Our customized hydraulic valve blocks represent the top level of hydraulic control t
Contact Now