Flow Control Valve Parts EC10-42-0-80Pressure compensation valveThreaded cartridge type, priority type, pressure compensation with static load sensing, used to prioritize the required flow rate, while using the remaining flow rate as an auxiliary functionWorking pressure: Oil inlet: 240barMaximum adjustable flow: compensation pressure 5.5 bar: 30.2lpmCompensation pressure: 5.5barTemperature range: -40°C-120°CProduct applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
  Contact Now
Flow Control Valve Parts EC42-M42-0-N-80 Pressure compensation valve, threaded cartridge type, priority type, pressure compensation with static load sensingWorking pressure: 241BarMaximum inlet flow: 80gpmMaximum priority flow: pressure 10.3 bar: 55.0gpm              Pressure 5.5 bar: 40.0gpmMaximum bypass flow: pressure 10.3 bar: 55.0gpm              Pressure 5.5 bar: 40.0gpmTemperature range: -40°C-120°C (standard nitrile rubber seal)Product applicationProduct LineOur WarehousePacking and TransportationPlease leave a
  Contact Now
Check Valve Parts PC08-30-0-NThreaded cartridge hydraulic check valve is used as a one-way cut-off or load holding equipmentWorking pressure 240barWithstand pressure 350barWhen the internal leakage is at 240bar, the maximum is 0.01ML/minTemperature range -40℃-120℃Seals: Nitrile rubber O-ring and retaining ring (standard type)Medium: Mineral oil with a viscosity between 7.4-420cSt (50-2000ssu) or synthetic oil with lubricating propertiesDetailed parametersWorking pressure Liquid control ratioCheck valve spring pre-pressure Use a sealed piston: Temperature range SealsMedium240bar 3:11.72bar, sta
  Contact Now
Solenoid Valve PartsUsed as cut-off or load-holding oil equipment in low-flow oil circuitsWorking pressure: 207barWithstand pressure: 255barTemperature range: -40°C-120°C standard nitrile rubber sealProduct applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
  Contact Now
Solenoid valve setDetailed parametersP port pressureMaximum flowVoltage rangeAccumulator volumeAllowable ambient operating temperatureOil temperature range40bar15L/minDC27V±15%; plug DTO4-2P, rated power 23.8W, protection level IP670.32L, precharge pressure 10bar-20-80℃-20-90℃Product applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
  Contact Now
Solenoid Valve Parts SD4E-A4/H2Y21Two-position four-way directional control valve, electromagnetic control spool valve type, direct-acting high-performance typeMaximum flow rate 30L/minMaximum working pressure 350barOperating ambient temperature range -20°C-80°C、Fluid temperature range -20°C-80°CProduct applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
  Contact Now
Counter valveDetailed parametersMaximum pressureMaximum flowHydraulic control check valve guide pressure ratioAllowable ambient operating temperatureThe oil temperature range350bar30L/min5:1-20-80℃-20-90℃Product applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
  Contact Now
hydraulic solenoid valveDetailed parametersRated pressureMaximum flowVoltage range Coil built-in diodeAllowable ambient operating temperatureOil temperature range70bar30L/minDC27V±15%; plug DTO4-2P, Rated power 23.8W, protection level IP67model RL257, Rated reverse voltage 1000V, rated current 2.5A, instantaneous peak current 100A-20-80℃-20-90℃Application Scenarios:Our customized hydraulic valve blocks represent the top level of hydraulic control technology, designed with a focus on performance, reliability and durability.
  Contact Now
hydraulic solenoid valveDetailed parametersMaximum working pressureMaximum decompression pressureRated flow rateProportional valveMaximum currentProtection levelAllowable pollutionSwitch valveAllowable ambient operating temperatureThe oil temperature range50 bar30 bar10L/minRated voltage: 24V, connector DT04-2P750mA, resistance: 20.8 Ω±5%IP6k6/IPX9K ISO 4406 class 20/18/15Voltage range DC27V±15%, plug DTO4-2P, protection level IP67;-20-80℃-20-90℃It is mainly composed of valve body, valve, electromagnet, etc.Among them, the valve is the most critical part of the quadruple solenoid valve.
  Contact Now
Pilot oil source valve type CDetailed parametersP port pressureMaximum flow rateVoltage rangeRated powerProtection levelAccumulator volumeAllowable ambient working temperatureOil temperature range350bar15L/minDC14V±15%; plug DTO4-2P23.8WIP670.32L, precharge pressure 15bar -20-80℃-20-90℃The interaction between the main valve core and the pilot valve core in the hydraulic system, and the output performance of the hydraulic system is controlled by adjusting the pilot valve.The pilot valve is usually a small-sized control valve, mostly a pressure control valve.
  Contact Now
directional valve Customized hydraulic valve set C020Detailed parametersElectromagnet voltageElectromagnetic coilOil rangeAllowable working ambient temperatureWorking oil temperature rangeDC27±15%protection level IP67HOUSING:174354-2PLATE:174355-7PIN:173706-1RUBBER PLUG:172888-2ISO 10-420Allowable pollution: ISO4406 class21/19/16;-20~80 C-30~90 CParameter:The maximum pressure of the P port 240 barMaximum flow30L/minVoltage rangeDC24V±15%; plug DTO4-2P, rated power 23.8W, protection level IP67Allowable ambient operating temperature-20-80℃The oil temperature range20-90℃Application Scen
  Contact Now
Customized hydraulic valve block HIC101000332Detailed parametersThe maximum pressure of the P port Maximum flow Voltage rangeAllowable ambient operating temperatureThe oil temperature range 240bar30L/minDC24V±15%; plug DTO4-2P, rated power 23.8W, protection level IP67-20-80℃20-90℃Product applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
  Contact Now
Manual descending hydraulic valveParameter:The maximum pressure of the P port 240 barMaximum flow30L/minVoltage rangeDC24V±15%; plug DTO4-2P, rated power 23.8W, protection level IP67Allowable ambient operating temperature-20-80℃The oil temperature range20-90℃Application Scenarios:Our customized hydraulic valve blocks represent the top level of hydraulic control technology, designed with a focus on performance, reliability and durability.
  Contact Now
Two solenoid hydraulic valvesDetailed parametersRated pressureMaximum decompression pressureProportional valve 2 Rated voltageMaximum coil currentCoil resistance at 20℃Optimized PWM frequencySolenoid valve 3 rated voltageAllowable ambient operating temperatureOil temperature range50 bar30 barDC 24V500mA31Ω±5 %600HZ, connector DT04-2PDC24V±10%, connector DT04-2P -20-80℃The working principle of the two-in-one solenoid valve mainly involves the interaction of the electromagnet, the valve body and the valve core, and controls the mechanical movement by controlling the current on and off of the ele
  Contact Now
Hydraulic Valve Block DPH-0115-12Parameter:The maximum pressure of the P port 240 barMaximum flow30L/minVoltage rangeDC24V±15%; plug DTO4-2P, rated power 23.8W, protection level IP67Allowable ambient operating temperature-20-80℃The oil temperature range20-90℃Application Scenarios:Our customized hydraulic valve blocks represent the top level of hydraulic control technology, designed with a focus on performance, reliability and durability.
  Contact Now
Customized hydraulic valve setDetailed parametersRated pressureSystem oilRated voltageOil port specificationsIntegrated block materialAccumulator Volume:FilterPressure setting40 BarHydraulic oil: Mineral hydraulic oil of ISO VG32, 46 and 68Viscosity range: 10-500 mm2/sCleanliness level: 21/18/15 According to ISO4406 (1999)Oil temperature range: -20~80℃27V±15%, connector DT04-2P P T PORT: G3/4-ED (DIN3852-2); A PORT: G3/8-ED (DIN3852-2);P1,P2, C1-C6, M,M1: G1/4-ED (DIN3852-2); M,M1 is blocked with steel.AL-6061-T6, surface anodized1L; inflation pressure: 15 baraccuracy 10um; flow rate: 160L/min
  Contact Now
Can be customized according to customer needs Customized case:1.Maximum working pressure: 50 bar; 2.Maximum decompression pressure: 30 bar; 3.Rated flow rate: 10L/min; 4.Rated voltage: 12V, connector DT04-2P, protection level IP67; 5.Maximum current: 1500mA, resistance: 4.72 Ω±5%; 6.Filter: 140 µm (P-Port); 7.Protection level: IP6k6/IPX9K.
  Contact Now
PrincipleElectromagnetic reversing valve is a device that uses the principle of electromagnetic mechanics to control the state of the oil port.
  Contact Now
The solenoid valve, made from hardened precision parts, provides high flow capacity and efficient hydraulic energy transmission, with all ports capable of full pressure loading. Application1. Application in the field of industrySolenoid valves are widely used in various industrial automation systems, such as transmission line, robot, metallurgy, chemical industry, water conservancy, electric power and other fields.
  Contact Now
The working principle of the solenoid valve is that it contains a closed cavity inside the solenoid valve. In the middle of the cavity is a piston, and on both sides of the cavity are two electromagnets.
  Contact Now
Solenoid Valve Parts SD2E-A4/H2R21Product applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
  Contact Now
Solenoid Valve Parts SP2A-B3H3S-AProduct applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
  Contact Now
The double solenoid valve belongs to a kind of solenoid valve, and its structure is composed of an electromagnetic spring ring, a valve body, a piston, a spring, a valve seat, a gasket and other parts.Its main feature is that it has two outlets and one inlet, each outlet has a piston, and the entire device is equivalent to two check valves.structureThe double solenoid valve is composed of two parts: an electromagnet and a valve body.The electromagnet is composed of three parts: a coil, a contact, and an iron core.
  Contact Now
Solenoid Reversing Valve Parts SD1E-A2/H2S5-ATwo-position two-way directional control valve, electromagnetic control, cone valve type, no leakage, direct-actingTwo-position two-way high-pressure direct-acting spool valve type threaded cartridge reversing valve.
  Contact Now
Relate News
Key points of knowledge about hydraulic valves(1) One-way valve1. Ordinary one-way valves only allow oil in one direction to pass through, and block the flow in the other direction. The control port of the one-way valve is connected to high-pressure oil, which can flow in the opposite direction. However, it should be noted that when the control oil port is not working, it must be connected to the oil tank, otherwise it will be difficult to reset.2. When the one-way valve is used to control the opening and closing of the oil circuit, the opening pressure is 0. 03- 0.
The hydraulic transmission system is an integral part of the hydraulic machinery. The design of the hydraulic transmission system must be carried out at the same time as the overall design of the host machine.
Liwei Hydraulic Technology Co., Ltd., founded in 2009, located in Jinan city, Shandong Province, is a high-tech enterprise dedicated to the research and development of hydraulic and electrical components, whether it is a single component or the whole system solution, Liwei hydraulic is your reliable partner. The products are widely used in construction machinery excavators, aerial working platform, loaders, rollers, pavers, cranes, agricultural machinery tractors, combine harvesters and other fields.
Because it is difficult to understand the flow conditions of parts and pipelines in a hydraulic station from the outside, many friends who are new to the hydraulic industry have many difficulties in analysis and diagnosis. Therefore, today I will teach you how to find out the faults of the hydraulic station.
The pressure in the hydraulic system is abnormal and the pressure cannot go up or down. Pressure is one of the two most basic parameters of the hydraulic system, which to a large extent determines the performance of the hydraulic system. This fault manifests itself as follows: when adjusting the pressure of the hydraulic system, the adjustment failure occurs, the system pressure cannot be established, the pressure is insufficient, or there is no pressure, or it rises and then falls, the adjusted pressure is unstable, and the pressure fluctuates greatly.1.