(Total 24 Products for DPH-0115-12)
Hydraulic Valve Block DPH-0115-12Parameter:The maximum pressure of the P port 240 barMaximum flow30L/minVoltage rangeDC24V±15%; plug DTO4-2P, rated power 23.8W, protection level IP67Allowable ambient operating temperature-20-80℃The oil temperature range20-90℃Application Scenarios:Our customized hydraulic valve blocks represent the top level of hydraulic control technology, designed with a focus on performance, reliability and durability.
  Contact Now
Check Valve Parts CV08-005Threaded cartridge hydraulic check valve is used as a one-way cut-off or load holding equipmentWorking pressure 240barWithstand pressure 350barWhen the internal leakage is at 240bar, the maximum is 0.01ML/minTemperature range -40℃-120℃Seals: Nitrile rubber O-ring and retaining ring (standard type)Medium: Mineral oil with a viscosity between 7.4-420cSt (50-2000ssu) or synthetic oil with lubricating propertiesDetailed parametersWorking pressureWithstand pressureWhen the internal leakageTemperature range SealsMedium 240bar350barAt 240bar, the maximum is 0.01ML/min-40℃-12
  Contact Now
The double solenoid valve belongs to a kind of solenoid valve, and its structure is composed of an electromagnetic spring ring, a valve body, a piston, a spring, a valve seat, a gasket and other parts.Its main feature is that it has two outlets and one inlet, each outlet has a piston, and the entire device is equivalent to two check valves.structureThe double solenoid valve is composed of two parts: an electromagnet and a valve body.The electromagnet is composed of three parts: a coil, a contact, and an iron core.
  Contact Now
Coil Parts C19-014DC-E8Features: Wide range of voltage; power supply Steel structure shell, strong resistance to mechanical damage; durableStrong high temperature resistance;Rated voltage (V) 14VDCElectrical connector type: double wireThe inner diameter of the coil is 14mmProduct applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
  Contact Now
The working principle of the solenoid valve is that it contains a closed cavity inside the solenoid valve. In the middle of the cavity is a piston, and on both sides of the cavity are two electromagnets.
  Contact Now
Solenoid valve setDetailed parametersP port pressureMaximum flowVoltage rangeAccumulator volumeAllowable ambient operating temperatureOil temperature range40bar15L/minDC27V±15%; plug DTO4-2P, rated power 23.8W, protection level IP670.32L, precharge pressure 10bar-20-80℃-20-90℃Product applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
  Contact Now
hydraulic solenoid valveDetailed parametersRated pressureMaximum flowVoltage range Coil built-in diodeAllowable ambient operating temperatureOil temperature range70bar30L/minDC27V±15%; plug DTO4-2P, Rated power 23.8W, protection level IP67model RL257, Rated reverse voltage 1000V, rated current 2.5A, instantaneous peak current 100A-20-80℃-20-90℃Application Scenarios:Our customized hydraulic valve blocks represent the top level of hydraulic control technology, designed with a focus on performance, reliability and durability.
  Contact Now
Solenoid Valve Parts SD2E-A4/H2R21Product applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
  Contact Now
hydraulic solenoid valveDetailed parametersMaximum working pressureMaximum decompression pressureRated flow rateProportional valveMaximum currentProtection levelAllowable pollutionSwitch valveAllowable ambient operating temperatureThe oil temperature range50 bar30 bar10L/minRated voltage: 24V, connector DT04-2P750mA, resistance: 20.8 Ω±5%IP6k6/IPX9K ISO 4406 class 20/18/15Voltage range DC27V±15%, plug DTO4-2P, protection level IP67;-20-80℃-20-90℃It is mainly composed of valve body, valve, electromagnet, etc.Among them, the valve is the most critical part of the quadruple solenoid valve.
  Contact Now
Solenoid reversing valvedirectional valve1. Control the pressure of the hydraulic systemThe hydraulic control valve can change the pressure and stability of the hydraulic system by adjusting the opening size and opening method in the valve core, so as to meet the work needs of different pressure requirements. 2.
  Contact Now
Solenoid Valve Parts SP2A-B3H3S-AProduct applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
  Contact Now
Two solenoid hydraulic valvesDetailed parametersRated pressureMaximum decompression pressureProportional valve 2 Rated voltageMaximum coil currentCoil resistance at 20℃Optimized PWM frequencySolenoid valve 3 rated voltageAllowable ambient operating temperatureOil temperature range50 bar30 barDC 24V500mA31Ω±5 %600HZ, connector DT04-2PDC24V±10%, connector DT04-2P -20-80℃The working principle of the two-in-one solenoid valve mainly involves the interaction of the electromagnet, the valve body and the valve core, and controls the mechanical movement by controlling the current on and off of the ele
  Contact Now
Please leave a message or send an email for details to ensure that you are satisfied with the price1.
  Contact Now
Solenoid Valve PartsUsed as cut-off or load-holding oil equipment in low-flow oil circuitsWorking pressure: 207barWithstand pressure: 255barTemperature range: -40°C-120°C standard nitrile rubber sealProduct applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
  Contact Now
Solenoid Reversing Valve Parts SD1E-A2/H2S5-ATwo-position two-way directional control valve, electromagnetic control, cone valve type, no leakage, direct-actingTwo-position two-way high-pressure direct-acting spool valve type threaded cartridge reversing valve.
  Contact Now
Two-position three-way solenoid hydraulic valveDetailed parameters:Working pressureMaximum flow rateVoltage rangePlug connection modelElectromagnetic coil protection levelSolenoid valve powerCheck valve opening pressureAllowable pollutionAllowable working ambient temperatureOil viscosity range50bar30L/min DC27V±15% DT04-2PIP67<30W1bar, diameter 821/18/15 -30℃--90℃ ISO 20--400mm2/SApplication Scenarios:Our customized hydraulic valve blocks represent the top level of hydraulic control technology, designed with a focus on performance, reliability and durability.
  Contact Now
Solenoid Valve Parts SD4E-A4/H2Y21Two-position four-way directional control valve, electromagnetic control spool valve type, direct-acting high-performance typeMaximum flow rate 30L/minMaximum working pressure 350barOperating ambient temperature range -20°C-80°C、Fluid temperature range -20°C-80°CProduct applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
  Contact Now
hydraulic solenoid valve Structure and flow path diagramTwo-position six-way directional control valve, also known as two-position six-way control valve, its main structure is composed of import and export interface, valve body, valve core, control lever and other parts, wherein the valve body is provided with a corresponding flow channel, used to control the direction of fluid in and out.The flow path diagram is shown below:Among them, A, B, P, and C are the inlet, outlet, internal connection port, and control port respectively.Among them, ports A and B can be connected to different hydraulic
  Contact Now
Solenoid Valve Parts SV08-20HJ-O-N-OUsed as cut-off or load-holding oil equipment in low-flow oil circuitsWorking pressure 207barWithstand pressure 255barThe maximum internal leakage is 0.15ml/min at 207barTemperature range -40°C-120°C, standard nitrile rubber sealThe rated load of the coil can operate continuously in the rated voltage range of 85% to 115% Product applicationProduct LineOur WarehousePacking and TransportationPlease leave a message or send an email for details to ensure that you are satisfied with the price
  Contact Now
Can be customized according to customer needs Customized case:1.Maximum working pressure: 50 bar; 2.Maximum decompression pressure: 30 bar; 3.Rated flow rate: 10L/min; 4.Rated voltage: 12V, connector DT04-2P, protection level IP67; 5.Maximum current: 1500mA, resistance: 4.72 Ω±5%; 6.Filter: 140 µm (P-Port); 7.Protection level: IP6k6/IPX9K.
  Contact Now
PrincipleElectromagnetic reversing valve is a device that uses the principle of electromagnetic mechanics to control the state of the oil port.
  Contact Now
The solenoid valve, made from hardened precision parts, provides high flow capacity and efficient hydraulic energy transmission, with all ports capable of full pressure loading. Application1. Application in the field of industrySolenoid valves are widely used in various industrial automation systems, such as transmission line, robot, metallurgy, chemical industry, water conservancy, electric power and other fields.
  Contact Now
Customized hydraulic valve setDetailed parametersRated pressureSystem oilRated voltageOil port specificationsIntegrated block materialAccumulator Volume:FilterPressure setting40 BarHydraulic oil: Mineral hydraulic oil of ISO VG32, 46 and 68Viscosity range: 10-500 mm2/sCleanliness level: 21/18/15 According to ISO4406 (1999)Oil temperature range: -20~80℃27V±15%, connector DT04-2P P T PORT: G3/4-ED (DIN3852-2); A PORT: G3/8-ED (DIN3852-2);P1,P2, C1-C6, M,M1: G1/4-ED (DIN3852-2); M,M1 is blocked with steel.AL-6061-T6, surface anodized1L; inflation pressure: 15 baraccuracy 10um; flow rate: 160L/min
  Contact Now
The lower oil cylinder, used for lifting cylinder action control, features throttle damping for descent speed regulation, precise flow control through a proportional valve, and minimal vibration. It includes a solenoid valve with manual operation for platform descent in the absence of power and an overflow valve for oil circuit safety. The function of the lifting oil cylinderLift cylinder is to use liquid medium to convert mechanical energy into hydraulic energy, and through operation to achieve load lift or drop.
  Contact Now
Relate News
Key points of knowledge about hydraulic valves(1) One-way valve1. Ordinary one-way valves only allow oil in one direction to pass through, and block the flow in the other direction. The control port of the one-way valve is connected to high-pressure oil, which can flow in the opposite direction. However, it should be noted that when the control oil port is not working, it must be connected to the oil tank, otherwise it will be difficult to reset.2. When the one-way valve is used to control the opening and closing of the oil circuit, the opening pressure is 0. 03- 0.
The hydraulic transmission system is an integral part of the hydraulic machinery. The design of the hydraulic transmission system must be carried out at the same time as the overall design of the host machine.
Liwei Hydraulic Technology Co., Ltd., founded in 2009, located in Jinan city, Shandong Province, is a high-tech enterprise dedicated to the research and development of hydraulic and electrical components, whether it is a single component or the whole system solution, Liwei hydraulic is your reliable partner. The products are widely used in construction machinery excavators, aerial working platform, loaders, rollers, pavers, cranes, agricultural machinery tractors, combine harvesters and other fields.
Because it is difficult to understand the flow conditions of parts and pipelines in a hydraulic station from the outside, many friends who are new to the hydraulic industry have many difficulties in analysis and diagnosis. Therefore, today I will teach you how to find out the faults of the hydraulic station.
The pressure in the hydraulic system is abnormal and the pressure cannot go up or down. Pressure is one of the two most basic parameters of the hydraulic system, which to a large extent determines the performance of the hydraulic system. This fault manifests itself as follows: when adjusting the pressure of the hydraulic system, the adjustment failure occurs, the system pressure cannot be established, the pressure is insufficient, or there is no pressure, or it rises and then falls, the adjusted pressure is unstable, and the pressure fluctuates greatly.1.